Product description

Parker Racor Turbine 500FG separates water and solid contaminants from fuel, protecting the fuel system. Preferably installed on the suction side, it subjects the fluid to centrifugal separation, coalescence and final filtration through an Aquabloc cartridge. The water collected in the clear bowl is removed via the bottom drain.

Benefits

  • Triple-action separation and filtration to remove free water, dispersed droplets and fine particles.
  • Protects the engine from corrosion, malfunctions and wear caused by fuel contamination.
  • Available with 10 or 30 micron filtration for different application requirements.

Features

  • Painted aluminium alloy body and clear bowl for checking the collected water.
  • Maximum flow rate of 227 l/h and maximum operating pressure of 1.03 bar.
  • 3/4"-16 UNF connections compliant with SAE J1926.
  • Dimensions: 290.8 mm × 105 mm × 105 mm; weight 1.8 kg.
  • Top clearance required for cartridge servicing: 101.6 mm.

Variant comparison

Data valid for the entire product range.
PARAMETER
Parker Racor serie Turbine Filtro Separatore

10 μm

500FG10
€ 733,22 Including 22% VAT € 601,00 Excluding VAT
30 μm

30 μm

500FG30
€ 733,22 Including 22% VAT € 601,00 Excluding VAT
Parker Racor Turbine 500 - Marino Coppetta Metallica | 227 l/h

Marine Metal Bowl | 227 l/h

500MAM10
€ 1.017,48 Including 22% VAT € 834,00 Excluding VAT
Parker Racor serie Turbine Filtro Separatore

Marine RINA Kit | 227 l/h

500MA10-R
€ 793,98 Including 22% VAT € 650,80 Excluding VAT
Marine | 227 l/h

Marine | 227 l/h

500MA10
€ 968,68 Including 22% VAT € 794,00 Excluding VAT
Double Marine | 454 l/h

Double Marine | 454 l/h

75500MAXM
€ 3.218,86 Including 22% VAT € 2.638,41 Excluding VAT
Height (mm) 290 290 273 274 274 290
Width (mm) 165 165 165 165 165 368
Length (mm) 131 131 131 131 131 251
Weight (kg) 1.8 1.8 2.2 1.8 1.8 7.7
Filtration grade 10 30 10 10 10 10
Nominal filtration (micron) 10 30 10 10 10
Flow rate 227 227 227 227 227 454
Flow rate unit L/H L/H L/H L/H L/H L/H
Pressure (bar) 1.03 1.03 1.03 1.03 1.03 1.03
Connections 3/4"-16 3/4"-16 3/4"-16 3/4"-16 3/4"-16 3/4"-16
Connection standard UNF UNF UNF UNF UNF UNF

FAQ

Tutto ciò che devi sapere su Parker Racor Turbine 500.

Tutte le configurazioni della pagina sono identiche?

Quale cartuccia va utilizzata nella Turbine 500?

Come si controlla l’acqua raccolta?

Altre domande su spedizioni, pagamenti e assistenza →

Fuel and hydraulic oil filtration systems for industrial machinery

Discover all products

Not just a technical partner, but a consultant who supports you with maintenance

Our support services